Monitored PDU - PDB-193-H 32

Description
PDU - Details / Function:
1. Enclosure: Sheet metal / black
2. LCD display on the device and monitoring via the console:
Monitoring of total load current,
Total voltage, total power, total energy,
Power factor, load current of each individual unit and
On/off status of each individual unit.
3. Support:
TCP/IP, SNMP V1/V2C/V3, Http/Https, IPV4/IPV6, SMTP, MODBUS
4. Upstream fuse: Schneider, IC65N 4P 40A 30 mA (= Type A version)
5. Output fuse of the outlet sockets: Chint, NXB-C16A/2P
6. Outlets: 9x Schuko (3x Schuko per phase)
7. 32A IP44 industrial plug (plug + socket, 5-pin, 6h)
8. Horizontal installation
Explanation:
RCD protection is very important for people, which is why we equip the PDU with a 30 mA Type A RCD as standard. With regard to a UPS, it is important to keep an eye on direct currents, because a Type A is not suitable for this; you need a Type B circuit breaker. That's why we offer you two options for selection. We recommend only the Type B variant for use with a UPS!
Technical Data
Specifications
| Type | Basic PDB-193-H |
|---|---|
| Input | 230/400VAC - 32A (3 phase) |
| Output | 230VAC - 9x Schuko |
| Expansion | Cascade up to 9 units, all monitored |
| Dimensions | W 433 mm x D 200 mm x H 320 mm |
PDU - Details / Function:
1. Enclosure: Sheet metal / black
2. LCD display on the device and monitoring via the console:
Monitoring of total load current,
Total voltage, total power, total energy,
Power factor, load current of each individual unit and
On/off status of each individual unit.
3. Support:
TCP/IP, SNMP V1/V2C/V3, Http/Https, IPV4/IPV6, SMTP, MODBUS
4. Upstream fuse: Schneider, IC65N 4P 40A 30 mA (= Type A version)
5. Output fuse of the outlet sockets: Chint, NXB-C16A/2P
6. Outlets: 9x Schuko (3x Schuko per phase)
7. 32A IP44 industrial plug (plug + socket, 5-pin, 6h)
8. Horizontal installation
Explanation:
RCD protection is very important for people, which is why we equip the PDU with a 30 mA Type A RCD as standard. With regard to a UPS, it is important to keep an eye on direct currents, because a Type A is not suitable for this; you need a Type B circuit breaker. That's why we offer you two options for selection. We recommend only the Type B variant for use with a UPS!
Specifications
| Type | Basic PDB-193-H |
|---|---|
| Input | 230/400VAC - 32A (3 phase) |
| Output | 230VAC - 9x Schuko |
| Expansion | Cascade up to 9 units, all monitored |
| Dimensions | W 433 mm x D 200 mm x H 320 mm |